Categories

  • Health and Harmony Kits
    Perfect for the
    Classroom!
    Watch the video!

    Shop Now

Hall Effect In P-germanium

Hall Effect In P-germanium

Hall Effect In P-germanium

The resistivity and Hall voltage of a rectangular germanium sample are measured as a function of  temperature and magnetic field. The band spacing, the specific conductivity, the type of charge carrier and the mobility of the charge carriers are determined from the measurements

P2530101

Call for Pricing!

More info

Principle:


The resistivity and Hall voltage of a rectangular germanium sample are measured as a function of  temperature and magnetic field. The band spacing, the specific conductivity, the type of charge carrier and the mobility of the charge carriers are determined from the measurements

Tasks:


1. The Hall voltage is measured at room temperature and constant magnetic field as a function of the control current and plotted on a graph (measurement without compensation for defect voltage).
2. The voltage across the sample is measured at room temperature and constant control current as a
function of the magnetic induction B.
3. The voltage across the sample is measured at constant control current as a function of the temperature.  The band spacing of germanium is calculated from the measurements.
4. The Hall voltage UH is measured as a function of the magnetic induction B, at room temperature.

The sign of the charge carriers and the Hall constant RH together with the Hall mobility mH and the carrier concentration p are calculated from the measurements.5. The Hall voltage UH is measured
as a function of temperature at constant magnetic induction B and the values are plotted on a
graph.

What you need:

Hall effect module 11801.001
Hall effect, p-Ge, carrier board11805.011
Coil, 600 turns06514.012
Iron core, U-shaped, laminated06501.001
Pole pieces, plane, 30 x 30 x 48 mm, 1 pair06489.001
Hall probe, tangential, with protective cap13610.021
Power supply 0-12 V DC/ 6 V, 12 V AC13505.901
Tripod base -PASS-02002.551
Support rod -PASS-, square, l = 250 mm02025.551
Right angle clamp -PASS-02040.551
Connecting cable, 4 mm plug, 32 A, red, l = 50 cm07361.013
Connecting cable, 4 mm plug, 32 A, blue, l = 50 cm07361.042
Connecting cable, 4 mm plug, 32 A, black, l = 75 cm07362.052
Teslameter, digital13610.901
Digital multimeter 201007128.001

Complete Equipment Set, Manual on CD-ROM included

 